Hardware Specifications |
|
Copper Ports |
LAN: 5 10/100/1000Mbps auto MDI/MDI-X RJ45 port (Port 1 to Port 5, bridge mode) |
|
WAN: 1 10/100/1000Mbps auto MDI/MDI-X RJ45 port (Port 5, gateway mode) |
|
PoE Injector Port |
4 ports with 802.3af/802.3at PoE injector function (Port 1 to Port 4) |
|
USB |
1 USB Type A female for setting backup |
|
Power Output |
4 PoE out 51VDC; max. 30 watts per PoE port |
|
2 DC out 24@ 1A maximum (four-pin terminal block) |
|
* The voltage of DC out is based on the battery. |
|
Switch Architecture |
Store-and-Forward |
|
Switch Fabric |
10Gbps/non-blocking |
|
Switch Throughput@64 bytes |
5.95Mpps@64 bytes |
|
MAC Address Table |
8K entries |
|
Shared Data Buffer |
512Kbit |
|
Flow Control |
IEEE 802.3x pause frame for full-duplex |
|
Back pressure for half-duplex |
|
Reset Button |
< 5 sec: System reboot |
|
> 5 sec: Factory default |
|
LED |
3 LEDs for System and Power: |
|
|
|
Green: Power |
|
Green: Fault |
|
Green: System |
|
|
|
4 LEDs for PoE Copper Ports (Port 1~Port 4): |
|
|
|
Green: LNK/ACT |
|
Orange: PoE-in-use |
|
|
|
1 LED for 10/100/1000T Copper Port (Port 5): |
|
|
|
Green: LNK/ACT |
|
|
|
3 LEDs for PoE Power Usage (W) |
|
|
|
Green: 50, 100 and 120W |
|
Connector |
Removable 6-pin terminal block |
|
Pin 1/2 for PV panel; Pin 3/4 for alarm; Pin 5/6 for battery |
|
Alarm |
1 Digital Output (DO): |
|
Level 0: -24V~2.1V (±0.1V) |
|
Level 1: 2.1V~24V (±0.1V) |
|
Open collector to 24V DC, 100mA max. |
|
Power Requirements |
PV in: 24~45V DC |
|
Battery in/out: 24V DC |
|
Power Consumption/ Dissipation |
5.04 watts, 17.1BTU (Standby without PoE function) |
|
6.96 watts, 23.7 BTU (Full loading without PoE function) |
|
135.36 watts, 461.5 BTU (Full loading with PoE function) |
|
Dimensions (W x D x H) |
84 x 107 x 152 mm |
|
Weight |
1026g |
|
ESD Protection |
6KV DC |
|
Enclosure |
IP30 aluminum case |
|
Installation |
DIN-rail kit and wall-mount ear |
|
Power over Ethernet |
|
PoE Standard |
IEEE 802.3af/802.3at Power over Ethernet PSE |
|
PoE Power Supply Type |
End-span |
|
PoE Power Output |
Per port 51V DC, 275mA. Max. 15.4 watts (IEEE 802.3af) |
|
Per port 51V DC, 535mA. Max. 30 watts (IEEE 802.3at) |
|
Power Pin Assignment |
1/2 (+), 3/6 (-) |
|
PoE Power Budget |
120 watts (PoE consumption + DC out and depending on power input) |
|
Max. Number of Class 2 PDs |
4 |
|
Max. Number of Class 3 PDs |
4 |
|
Max. Number of Class 4 PDs |
4 |
|
Electrical Characteristics |
|
System Voltage Rating |
24V DC |
|
Maximum Charging Current |
15A |
|
Max. Solar Array VOC |
60V DC |
|
Max. Operating Voltage |
45V DC |
|
Total Current Consumption |
While operating -32Ma |
|
At idle -11mA |
|
High Temperature Shutdown |
100 degrees C disconnect solar and load |
|
80 degrees C reconnect solar and load |
|
Overload Capacity |
Over 15 Amp will cut off output load |
|
Battery Charging Characteristics |
|
Charge Algorithm |
Bulk charge (constant current), Absorption charge (constant voltage) and Floating charge. Absorption and Floating charge with PWM protection. |
|
Maximum Output Current |
15A |
|
Nickel-cadmium Battery |
± 40 mV/degrees Celsius for NiCad type batteries; charge cut-off @ 55 degrees C |
|
(Temperature compensation baseline@ 25 degrees C) |
|
Lead Acid Battery (Default Setting) |
± 60 mV/degrees Celsius for lead acid type batteries; charge cut-off @ 55 degrees C |
|
(Temperature compensation baseline@ 25 degrees C) |
|
Float Charge Voltage |
DC 27.2V (26.0~30.0V) |
|
Absorption Charge Voltage |
DC 29.2V (28.0~32.0V) |
|
LVD (Low Voltage Disconnection) |
DC 22.2V (21.0~25.0V) |
|
LVR (Low Voltage Reconnection) |
DC 24.8V (23.0~27.0V) |
|
Router Features |
|
Internet Connection Type |
Shares data and Internet access with users, supporting the following internet accesses: |
|
|
|
PPPoE |
|
Dynamic IP |
|
Static IP |
|
PPTP |
|
L2TP |
|
Firewall |
NAT firewall with SPI (Stateful Packet Inspection) |
|
Built-in NAT server supporting Port Forwarding, and DMZ |
|
Built-in firewall with IP address/MAC address/Port/ URL filtering |
|
Supports ICMP-FLOOD, UDP-FLOOD, TCP-SYN-FLOOD filter, DoS protection |
|
Routing Protocol |
Static/Dynamic (RIP1 and 2) routing |
|
VPN Pass-through |
PPTP, L2TP, IPSec, IPv6 |
|
LAN |
Built-in DHCP server supporting static IP address distribution |
|
Supports UPnP, Dynamic DNS |
|
Supports IGMP Proxy |
|
Supports 802.1d STP (Spanning Tree) |
|
IP/MAC-based bandwidth control |
|
Management |
|
Management Interface |
Setup of system/management functions |
|
Web firmware upgrade |
|
SNMP trap for alarm notification of events |
|
PoE Management |
Power limit by consumption and allocation |
|
PoE admin mode |
|
Per port power schedule |
|
Per port power enable/disable |
|
Power feeding priority |
|
Current per port usage and status |
|
Total power consumption |
|
PD alive check |
|
Scheduled power recycling |
|
Battery Management |
Battery current usage and status |
|
Battery capacity statistics |
|
Low Voltage Cut-Off Protection |
|
Standards Conformance |
|
Regulatory Compliance |
FCC Part 15 Class A, CE |
|
Standards Compliance |
IEEE 802.3 10BASE-T Ethernet |
|
IEEE 802.3u 100BASE-TX Fast Ethernet |
|
IEEE 802.3ab 1000BASE-T Gigabit Ethernet |
|
IEEE 802.3x Flow Control and Back Pressure |
|
IEEE 802.1D Spanning Tree Protocol |
|
IEEE 802.3af Power over Ethernet |
|
IEEE 802.3at Power over Ethernet Plus |
|
RFC 768: UDP |
|
RFC 791: IP |
|
RFC 2068 HTTP |
|
RFC 1157: SNMP v1 |
|
RFC 1902: SNMP v2c |
|
RFC 5424: Syslog |
|
Environment |
|
Operating |
Temperature: -10 ~ 60 degrees C |
|
Relative Humidity: 5 ~ 95% (non-condensing) |
|
Storage |
Temperature: -10 ~ 70 degrees C |
|
Relative Humidity: 5 ~ 95% (non-condensing) |